The PR 402 Abu Dhabi Lighting Design Manual (Version 3.0, July 2021) acts as the primary regulatory document for infrastructure lighting, focusing on energy efficiency and sustainability. It defines stringent standards for LED color temperature, durable materials, and specific lighting classes for roadways and tunnels to enhance safety and reduce power consumption. View the document for more information on the Scribd PR-402 lighting manual.

8. Luminaire & Pole Specifications

8.1 Luminaires

  • Ingress Protection: IP66 minimum for external roadside luminaires.
  • Impact resistance: IK08 for public realm (ground floor accessible).
  • Driver: Constant current, programmable, surge protection ≥ 10kV.

6.2 Required Deliverables (for PR 402 approval)

  • Photometric calculation file (.ldt or .ies).
  • Lighting layout drawing (scale 1:500 min).
  • Glare analysis (TI calculation for road sections).
  • Light pollution contour plot (showing property boundary spill).

Light correctly. Light responsibly. Light by PR 402.

Technical details regarding the "Dark Sky" requirements or LED binning.

Pr 402- Abu Dhabi Lighting Manual [top]

The PR 402 Abu Dhabi Lighting Design Manual (Version 3.0, July 2021) acts as the primary regulatory document for infrastructure lighting, focusing on energy efficiency and sustainability. It defines stringent standards for LED color temperature, durable materials, and specific lighting classes for roadways and tunnels to enhance safety and reduce power consumption. View the document for more information on the Scribd PR-402 lighting manual.

8. Luminaire & Pole Specifications

8.1 Luminaires

6.2 Required Deliverables (for PR 402 approval)

Light correctly. Light responsibly. Light by PR 402. pr 402- abu dhabi lighting manual

Technical details regarding the "Dark Sky" requirements or LED binning. The PR 402 Abu Dhabi Lighting Design Manual (Version 3