Jungheinrich Eje 120 Error Code 4372 Top [upd] Official
Title: [Help] Jungheinrich EJE 120 Error Code 4372 - Need advice on troubleshooting
- Pin 12: S4 signal input
- Pin 11: Ground return
Check for mechanical damage or wear in the traction sensor located within the drawbar head. Summary of Actions jungheinrich eje 120 error code 4372 top
Replace Tiller Head: If firmware updates do not resolve the issue, the tiller head unit or the internal sensor card may need to be replaced entirely. Title: [Help] Jungheinrich EJE 120 Error Code 4372
Specifically, the truck’s control unit (ELC) is not receiving a plausible signal from the drive motor’s rotational speed sensor. Because the controller cannot verify how fast the motor is spinning, it triggers a safety response: Pin 12: S4 signal input Pin 11: Ground return
Step 4: CAN Bus Termination Check
The EJE 120 uses a 120-ohm terminating resistor at both ends of the CAN bus (Master controller and Top module).