The DVB01 is a multifunctional voltage monitoring controller designed for high-accuracy direct voltage measurement (0V to 100V) and relay control. It features an industrial-grade microcontroller and offers five user-selectable functions. Core Specifications

Relay closes when the voltage is either below the lower limit or above the upper limit. 4. Parameter Programming (Setting Mode) Enter Settings: Long press to enter the selection interface (displays "P-0"). Select Parameter: Short press to cycle through parameters P-0 to P-5 Function Selection (F-01 to F-05). Lower Limit Voltage (0.0V to 99.9V). Upper Limit Voltage (0.0V to 99.9V). Voltage Calibration (match display to a known voltmeter). Delay for Relay Pull-in (0.0 to 99.9s). Delay for Relay Disconnect (0.0 to 99.9s). Adjust Values: buttons to change values. Use to switch between digits (flashing). Save & Exit: Long press to save all settings and return to normal operation. 5. Special Features dvb01 user manual