To download and use the verified BatteryView.exe software for Pylontech batteries, follow this guide for a safe installation and setup. Where to Download Verified BatteryView
Connection Procedure
Install the USB-to-RS485 driver (usually CH340 or FTDI).
Connect the adapter to the PC and the battery’s Link Port (RS485).
Open Device Manager and note the COM port number (e.g., COM3).
RunBatteryView.exeas Administrator (right-click → Run as administrator).
Go to Settings → Communication → Select the correct COM port and Baud rate (usually 9600 for Pylontech).
Click Open – if successful, you will see live data populate the grid.
Specifically: A cable with a USB-A head on one side and an RJ45 (or open wires) on the other.
Pinout: Connect to the BMS Port (Port 1 or Port 2) on the battery master module. usually Pin 7 (B) and Pin 8 (A) on the RJ45, though colors vary by adapter brand.